At what temperature should you enable the internal heaters in the ZF 7731?

Question

At what temperature should you enable the internal heaters in the ZF 7731?

Resolution

- The heater is off by default and it will turn on when the temperature reaches -1 deg Celsius and will turn off when it reaches +5 deg Celsius.
- The temperature point it uses as reference is the internal processor temperature and not the ambient or outside temperature.
-  The 7731 needs to be powered up via a PoE injector for Internal heater to work. 


You can check the temperature under Status-> Bridge after enabling the Internal heater. 